• その他のフルークグループ:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
フルークブランドをさらに表示
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
ホーム
Precision, Performance, Confidence.
フルーク・キャリブレーション - Fluke Calibration Japan
  • 登録
  • ログ・イン
  • Contact Us

JP - Japanese (日本語) [Change]

 

Get Quote

Replacing PACE 5000 with the 6270A Modular Pressure Controller/Calibrator

Document(s): 
application/pdf icon Replacing PACE 5000 with the 6270A Modular Pressure Controller/Calibrator (2.21 MB)

The PACE 5000 Replacement - the Fluke 6270A

The 6270A Modular Pressure Controller/Calibrator is an effective drop-in replacement for the GE Druck PACE 5000 Modular Pressure Controller/Indicator in most applications. This application note summarizes some of the benefits of upgrading to the 6270A, as well as detailing the steps for configuring and installing the 6270A as a replacement to the PACE 5000.

Benefits of upgrading

There are many benefits to upgrading to the 6270A Modular Pressure Controller/Calibrator, including:

  • Workload coverage
  • Control performance
  • Maintainability/serviceability
  • Expandability

Let’s explore these benefits in more detail.

Workload coverage

The PACE 5000 supports one pressure range at a time (for the dual channel version of PACE, see the application note “Replacing a PACE 6000 with the 6270A Modular Pressure Controller/ Calibrator”). The single module setup limits the range of pressure that a single PACE 5000 unit can cover. Theoretically, different range modules could be used to allow for wider range coverage, but replacing a module requires disconnecting all pressure and vacuum lines running to and from the instrument. The 6270A allows for up to five modules to be installed at one time and allows you to re-range the unit by quickly and easily replacing modules through the front panel.

Measurement performance

The PACE 5000 utilizes silicon-based pressure sensors for its on-board calibration reference standards. Its measurement specification is typically cited to be as good as 0.005 % reading +0.005 % full scale. This specification includes the combined effects of non-linearity, hysteresis, and repeatability. It does not include long-term stability, which is an additional 0.01 % reading per year. The specifications provided below for the Fluke Calibration 6270A include one-year measurement stability.

Fluke Calibration 6270A offers two pressure measurement module class options to balance cost and performance. The specifications provided for the 6270A are inclusive of all influences, including one-year stability.

  1. The silicon-based cost-effective PM200 module offers 0.02 % full scale total one-year measurement uncertainty specification.
  2. PM600 module offers 0.01 % reading total one-year measurement uncertainty specification from 30 % to 100 % of the module full scale. Most of the PM600 modules offer gauge, absolute and vacuum measurement standard.

Control performance

The 6270A provides control precision of ±0.001 % of the active range. This specification allows for proper pressure stability at both high and low pressures. For example, if the 6270A is configured with a 300 psi range and a 3000 psi range, then the control precision will be ±0.003 psi at lower pressures (300 psi and below) and ±0.03 psi for higher pressures. The PACE 5000 has a similar specification of ±0.001% full scale.

Maintainability and serviceability

The 6270A is designed with a focus on maintenance and service. The modular design allows for reduced downtime during recalibration. Control functionality is also encapsulated in a module, making troubleshooting and repair of any control performance issues. The focus on serviceability is seen throughout the design. For example, the removable connection manifold allows for easy repair if the port connection threads are damaged due to misuse.

Expandability

Your calibration needs change with time. The 6270A can change with your needs. You can change the pressure range or measurement performance of the instrument by adding pressure measurement modules. This can be done without sending any part of the instrument back to the factory for reconfiguration. Simply install the new Fluke pressure modules and start controlling pressure. You can install the new module in less than a minute, without having to change any of your pressure lines connected to the instrument. The system can then automatically switch between modules as necessary.

Configuring a 6270A

Selecting a pressure module

The PACE 5000 is available with a choice of three different accuracy classes (CM0, CM1, and CM2). The 6270A pressure modules are available in two accuracy classes, with the PM200 modules providing 0.02 % FS uncertainty for one year (for most ranges) and the PM600 providing 0.01 % reading uncertainty for one year.

Figure 1 shows a comparison of the specifications across the given pressure range. The uncertainty of the PACE 5000 has been estimated as the summation of the precision specification and the long-term stability specification.

Comparison of Estimated Measurement Uncertainty (gauge)
Figure 1. Comparison of percent full scale, percent reading, and percent reading plus percent full scale specifications.

* The exact range is not available, but the required range is within the percent reading region of the given PM600 range.

PACE 5000, SI units PACE 5000, psi   PM200 PM600
2.5 kPa 0.35 psi gauge PM200-BG2.5K -
7 kPa 1 psi gauge - PM600-BG15K*
20 kPa 3 psi gauge - -
35 kPa 5 psi gauge PM200-BG35K PM600-G100K*
70 kPa 10 psi gauge - PM600-G100K*
100 kPa 15 psi gauge PM200-BG100K PM600-G100K
200 kPa 30 psi gauge PM200-BG200K PM600-A350K*
350 kPa 50 psi gauge - PM600-A700K*
700 kPa 100 psi gauge PM200-G700K PM600-A700K
1 MPa 150 psi gauge PM200-G1M PM600-A1.4M
2 MPa 300 psi gauge PM200-G2M PM600-A2M
3.5 MPa 500 psi gauge PM200-G3.5M PM600-A3.5M
7 MPa 1000 psi gauge PM200-G7M PM600-A7M
10 MPa 1500 psi gauge PM200-G10M PM600-A10M
13.5 MPa 2000 psi gauge PM200-G14M PM600-A14M
17.2 MPa 2500 psi gauge - PM600-A20M
21 MPa 3000 psi gauge PM200-G20M PM600-A20M

Figure 2. Recommended ranges when replacing a PACE 5000 with a 6270A

The 6270A pressure modules are available in a number of ranges, as shown in Figure 2. The PM200 and PM600 provide different levels of performance, allowing it to cover many different applications.

Measuring barometric reference pressure

A barometric reference sensor is an available option on the PACE 5000. Choosing this option allows the instrument to be used in absolute mode. If gauge mode PM200 modules are used with the 6270A, then a barometric reference option is recommended for operation in absolute mode. There are two modules available that can be used for measuring the barometric reference pressure:

Model 1-year specification
PM200-A100K 0.1 % FS
BRM600-BA100K 0.01 % reading

When a barometric reference sensor is used to allow for absolute mode pressure measurements, the barometer’s performance has a greater impact on the overall measurement at lower pressures compared to higher pressures. For many applications, the PM200-A100K is acceptable for pressure ranges of 500 psi or greater. The BRM600- BA100K is preferred for lower pressure ranges.

The majority of PM600 modules are inherently absolute mode. They are capable of measuring in both gauge and absolute mode without the use of an additional barometer. Adding the barometer can improve the measurement performance in absolute mode. In most situations where the PACE 5000 measurement performance was acceptable, the additional improvements provided by the barometer are not necessary.

Selecting the test port manifold

There are three versions of the 6270A main chassis. The difference between the versions is the connection types on the back of the instrument. The connection types can be changed by removing and replacing the rear connection manifold. To remove the manifold, simply remove the four screws and slide the manifold out the back of the instrument. The pressure connections on the PACE 5000 are 1/8 BSP. Adaptors are available where necessary.

Model Supply, exhaust, test, and reference connections Vent connection
6270A-NPT 1/4 NPT 1/8 NPT
6270A-BSP 1/4 BSP (parallel) 1/8 BSP (parallel)
6270A-7/16 7/16-20 SAE 5/16-24 SAE

Installation and setup

Rackmount installation

An optional rackmount kit is available for the 6270A. This kit allows for installing the 6270A in a standard 19-inch rack, just like the optional rackmount kit that was available for the PACE 5000. The PACE 5000 is 2U high, where the 6270A is 3U. When replacing a PACE 5000 installed in a rack system, an additional 45 mm (1.75 inches) of vertical space is necessary.

Physical connections

Making pressure connections when replacing a PACE 5000 is straightforward. Simply connect the device under test to the 6270A test port instead of the PACE 5000 outlet. Connect the supply pressure (previously connected to the PACE 5000 supply+ port) to the supply port on the 6270A. If there was a vacuum pump connected to the PACE 5000 supply port, connect it to the 6270A exhaust port. For ranges above 100 psi, the supply pressure requirements for the PACE 5000 and the 6270A are the same (10% above the full-scale range). For ranges below 100 psi, increase the 6270A supply pressure to equal the full scale plus 15 psi (100 kPa).

Emulating remote communication

The 6270A can be placed in PACE 5000 remote emulation mode. To set remote emulation mode from the front panel, press SETUP. In the main setup menu, select INSTRUMENT SETUP and then REMOTE PORT. Pressing EMULATION MODE allows you to select PACE 5000. For a complete listing of all supported commands, see the 6270A Programmers Reference Guide. When using RS-232, the 6270A requires a null modem cable, where the PACE 5000 uses a straight cable. Null modem adaptors and cables are readily available.

Conclusion

The Fluke Calibration 6270A offers many benefits. The ability to use five modules simultaneously allows for wide pressure range coverage, and that coverage can be easily expanded as your needs change. A true modular design provides improved uptime. With the 6270A you get the service and support of Fluke Calibration, the industry leaders in pressure calibration.

  • ホーム
  • 製品
    • 新製品情報
    • 電気校正
      • 電気標準器
      • 電気校正器
      • ベンチ・マルチメーター
      • 電気校正ソフトウェア
    • RF 校正
      • RF リファレンス・ソース
      • RF 校正アクセサリー
      • RF 校正ソフトウェア
    • データ収集とテスト装置
      • ベンチ・マルチメーター
      • データ収集
      • データ収集ソフトウェア
    • 温度校正
      • ITS-90 温度標準器
        • ITS-90 定点セル
        • 標準白金抵抗温度計(SPRT)
        • メンテナンス装置
        • 液体窒素式比較校正装置
        • 抵抗ブリッジ
        • 標準抵抗器
      • 校正バス
        • 小型校正バス
        • 標準バス
        • 特殊アプリケーション用バス
        • バス用アクセサリー
        • バス・コントローラー
        • バス用温度媒体
      • 工業用温度校正器
        • フィールド・メトロロジー・ウエル
        • メトロロジー・ウェル
        • ハンドヘルド・ドライウェル校正器
        • フィールド・ドライウエル
        • 超小型バス
        • 赤外線校正器
        • 熱電対炉
        • デュアル・ブロック・ドライウエル
        • ゼロ点ドライウエル
      • プローブ/センサー
        • 白金抵抗温度計 (PRT)
        • サーミスター
        • 標準熱電対
      • デジタル温度指示計
      • マルチファンクション校正器
      • 温度校正ソフトウェア
    • 湿度校正
      • 湿度校正器
      • 湿度データ・ロガー/モニター
    • 圧力校正
      • ピストン・ゲージ
        • NMI ピストン・ゲージ
        • 絶対圧ピストン・ゲージ
        • 高圧力ガス・ピストン・ゲージ
        • 油圧式ピストン・ゲージ
        • ピストン・ゲージ用アクセサリー
      • 圧力コントローラー/校正器
        • 低圧力コントローラー/校正器
        • 空気式圧力コントローラー/校正器
        • 高圧空気式コントローラー/校正器
        • 油圧式コントローラー/校正器
      • 圧力モニター
        • 低圧力計
        • デジタル圧力計
        • 基準圧力モニター
      • 重錘形圧力計
        • 空気式デッドウェイト・テスター
        • 油圧式デッドウェイト・テスター
        • 液圧式デッドウェイト・テスター
        • 高圧油圧式デッドウェイト・テスター
        • デッドウェイト・テスター用アクセサリー
      • 手動校正器、モニター
        • 圧力校正器
        • 空気圧の制御
        • 液体圧比較器/ポンプ
      • Handheld Pressure Calibrators
      • エア・データ・テスト
      • ラボ環境モニター
      • 圧力校正アクセサリ
      • 圧力校正カスタム・システム
      • 圧力校正ソフトウェア
    • 流量校正
      • 気体流量標準器
      • 気体流量アクセサリ
      • GFS 質量流量一次標準
      • 流量校正ソフトウェア
    • プロセス校正ツール
      • 温度校正器
        • ハンドヘルド温度校正器
        • ドライブロック校正器およびマイクロバス
        • 高精度デジタル温度計
        • 温度プローブ
        • 赤外線温度計校正器
        • データ・ロギング機能付き湿温度計
      • 圧力校正器
        • デジタル圧力校正器
        • ハンドヘルド圧力校正器
        • 重錘形圧力計
        • 高精度デジタル圧力計
        • 校正用ハンド・ポンプ
      • マルチファンクション校正器
      • mA ループ校正器
      • プロセス校正ソフトウェア
    • 校正ソフトウェア
      • MET/CAL ソフトウェア
      • MET/CAL Support
      • 資産管理ソフトウェア
      • 温度校正ソフトウェア
      • 圧力校正ソフトウェア
      • 流量校正ソフトウェア
      • 機械/寸法校正ソフトウェア
    • サービスとサポート
    • すべての校正機器
  • ご購入について
    • 購入窓口
    • 見積依頼
    • デモ依頼
    • 相談/問い合わせ
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • ニュース
    • プレスリリース
    • プロモーション
    • 業界リンク
    • Metrology Salary Survey
  • トレーニングとイベント
    • 展示会/セミナー
    • トレーニング・コース
    • User Group Meetings
    • ウェブセミナー
      • ライブ・セミナー
      • 過去のセミナー(アーカイブ)
  • カタログ・資料
    • Education Hub
    • About Calibration
    • 参考資料
    • 製品資料
    • 製品マニュアル(ユーザー・ガイド)
    • Videos and Virtual Demos
    • Blog
  • サービスとサポート
    • Service Request (RMA)
    • Service Plans
    • ナレッジベース
    • 認定校正
    • サービスセンター
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • 製品マニュアル(ユーザー・ガイド)
    • 安全データ・シート(SDS)
    • 安全性および製品に関するお知らせ
    • ソフトウェア・ダウンロード
  • フルーク・キャリブレーション
    • お問い合わせ先
    • 所在地
    • キャリア
    • フルーク・キャリブレーションとは
      • Hart Scientific:温度校正
      • DH Instruments:圧力/流量校正
      • Pressurements:圧力校正
      • Ruska:圧力校正
    • 関連企業
    • 行動規範とコンプライアンス
    • よくある質問
ホーム|カタログ・関連資料|参考資料|圧力校正|アプリケーション・ノート|Replacing PACE 5000 with the 6270A Modular Pressure Controller/Calibrator
©1995-2022 Fluke Corporation
             

Secondary menu

  • 免責事項
  • プライバシー・ステートメント
  • Terms of Use
  • Terms and Conditions of Sale